TM 11-5895-846-14
(9) Loosen the twelve 1/4-turn fasteners
(13) Through the top access and front access
which secure the top cover.
openings, loosen the screw on each of the hose clamps
(10) Remove the top cover.
which secure the flexible plenum to the blower and
(11) Loosen the thirteen 1/4-turn fasteners
which secure the front access cover.
(14) Remove the flexible plenum.
(12) Remove the front access cover.
Figure 5-7. Power Amplifier, Front Access Opening, Removal Items.
(15) Loosen the five 1/4-turn fasteners which
(18) Remove the three blower power wires
secure the right side access cover.
from the terminal board.
(16) Remove the right side access cover.
(19) Remove the screw from the cable clamp
(17) Through the right side access opening
holding the blower cable to the klystron support.
remove three screws from terminals 1, 2, and 3 on
5-22