Table 3-1. Power Distribution Panel, Operator's Control and Indicators
Item
Fig.
No.
Control, indicator or connector
Function
reference.
PANEL, POWER DISTRIBUTION SM-F-935007 (POWER DISTRIBUTION PANEL)
1
NO GO
Indicator
When illuminated, indicates fault between the power
distribution panel and the applicable generator.
2
MAIN POWER-1 Circuit Breaker
When in the ON position, applies power from the NO. 1
primary power source to the panel breakers and switches.
3
POWER IN Indicator (left side)
When illuminated, indicates that primary power is available at
the MAIN POWER-1 circuit breaker.
4
AIR COND-1 Circuit Breaker
When in the ON position, applies power to the NO. 1 air
conditioner when MODE SELECT is in any of the first three
CW positions.
5
UTILITY Circuit Breaker
When in the ON position, applies power to the shelter utility
outlets.
6
LIGHTS Circuit Breaker
When in the ON position, applies power to the shelter lights.
7
AS-3199/TSC DEHYD Circuit Breaker
When in the ON position, applies power to the alternate
8
MODE SELECT switch
Provides selection of the required power amplifier and air
COND combination.
9
RACK 3 PA-1
When in the ON position, applies power to the rack 3 power
amplifier.
10
AUX
When in the ON position , applied power to the rack 3
upconverter.
11
RACK 1 Circuit Breaker
When in the ON position, applies power to rack 1.
12
TTY Circuit Breaker
When in the ON position, applies power to the TTY.
13
RACK 5 Circuit Breaker
When in the ON position, applies power to rack 5.
14
RACK 6 Circuit Breaker
When in the ON position, applies power to rack 6.
15
MONITOR AC Volt Meter
Provides for measuring terminal voltages from the AC power
16
Selector switch
Provides for switching meter to the s ix AC lines from the power
generator.
17
RACK 7 Circuit Breaker
When in the ON position, applies power to rack 7.
18
RACK 8 Circuit Breaker
When in the ON position, applies power to rack 8.
19
RACK 2 Circuit Breaker
When in the ON position, applies power to rack 2.
20
RACK 4 AUX Circuit Breaker
When in the ON position, applies power to the blower and all
equipment except the power amplifier.
21
PA-2 Circuit Breaker
When in the ON position, applies power to the blower and
power amplifier.
22
ANT RAD LIGHT DISABLE switch
23
BLACKOUT INHIBIT Circuit Breaker
When in the ON position, prevents the blackout circuit from
functioning when the shelter door is opened.
24
AIR COND-2 Circuit Breaker
When in the ON position, applies power to the NO. 2 air
conditioner when the MODE SELECT is in any position except
the third CW position.
25
GO Indicator
When illuminated, indicates power is available for distribution
from applicable circuit breakers.
26
MAIN POWER-2 Circuit Breaker
When in the ON position, applies power from the NO. 2
primary power source to the panel breakers and switches.
27
POWER IN indicator (right side)
When illuminated, indicates that primary power is available at
the MAIN POWER-2 circuit breaker.
Table 3-2. Track Patch Panel, Operator's Controls and Indicators
Item
Fig.
No.
Control, indicator or connector
function
reference.
1
D/C1 TRACK OUT connector
Provides tracking output termination from downconverter 1.
2
BEACON connector (behind sliding door)
Provides termination for the beacon signal.
3
COMM connector (behind sliding door)
4
D/C5 TRACK OUT) connector
Provides tracking output termination from downconverter 5.
5
COMM TRACK FILTER SELECT Switch.
Provides for selection of narrow or wide band filter.
3-19