TM 11-5895-846-14
Table 8-13. Alarm Monitor, Troubleshooting Chart - Continued
Item of Check
Test Conditions
Normal Indications
Remarks
c. On the UUT, connect one end of a
Pulsating tone.
If tone is not heard re-
test lead to ground and the other
place LS1.
lead to the MINUS (-) terminal
of LS1. Listen for the indications.
d. On the UUT place POWER cir-
cuit breaker (CB1) to the OFF
ing from S1-9 to chassis
position. Connect the multi-
ground.
meter (set for ohms) to ground
terminal 9 of switch S1.
After normal indication is ob-
tained, turn on POWER switch
S1. After normal indication is
obtained, turn on POWER
switch CB1.
e. On the UUT, place FAULT
Pulsating tone.
switch S1 to the NORMAL
is heard, check wiring
position. Connect one end
between XA1-8 and
of a test lead to ground and the
S1-8. If tone is heard
other end to pin 8 of chassis
proceed to step 4.
connector XA-1. Listen for
the indication.
a. On the UUT front panel press-
4.
Fault and safety in-
Momentarily ON.
dicator wiring.
to-test all the lamp indicators
dicator does not turn on
(except ac indicators). Ob-
check for + 24 V at pin 1
serve each indicator.
and pin 3 of the lamps socket.
Check wiring and repair as
required.
b. On the UUT, connect one end of
XA1-3, DS4: momentarily
If no indication, check
a test lead to ground. See figure
ON. (waveguide)
wiring between XA1-3
and XD54-2.
tarily connect the other end of the
test lead to XA1-3. Observe
indicator DS4 (WAVEGUIDE
INTERLOCK).
c. Repeat step b above but for the
XA1-4, DS5 (ANT)
If no indication, check
following pins and indicators
XA1-5, DS6 (RSS)
wiring between asso-
as listed in the Normal
XA1-6, DS2 (DC PWR)
ciated pin on XA1 and
indication column.
XA1-7, DS3 (CSS Temp)
2 on the lamp socket.
XA1-9, DS7 (CSS) all
momentarily ON.
a. Open the UUT access cover.
5.
Fault switch wiring.
DS8: Momentarily ON.
If no indication, check
wiring between XDS8-2
Momentarily place fault switch
and S2-6 and S2-2
1 (S2) to the OVERRIDE
and ground. Also
position and return to NOR-
check switch operation.
MAL. Observe OVERRIDE
indicator DS8.
b. Repeat step a above but for
DS8: Momentarily ON.
If no indication, check as-
fault switches 2 through 12
sociated switch and
(S3 through S13). Observe
wiring.
OVERRIDE indicator DS8.
c. On the UUT, connect the multi-
+ 5 V 0.5 V
If no indication, check
meter (set for dc volts) to XA1-26
S14 operation, wiring
(+) and ground. Momentarily
to unit connector P2,
and wiring to XA1-26.
SAFETY ALERT) to OVER-
RIDE and then release. Observe
8-38