Table 3-16. Remote Control, Operator's Control and Indicators
Item
Fig.
No.
Control, indicator or connector
Function
reference
CONTROL, ANTENNA SM-D-936104 (REMOTE CONTROL)
1
CARRIER LEVEL Meter
Measures received signal stren gth of 70 MHz tracking signal.
2
TRACK SIG LOSS
Illuminates when antenna tracking signal has been lost.
Indicator
3
AXIS CONTROL Switch
When in MANUAL mode and moved to selected position
(UP, R, DOWN, L) will cause antenna to travel in selected
direction.
4
MODE Switch
Provides for placing unit in selected (ACQ, MANUAL, or AUTO)
operating mode.
5
REMOTE ON Indicator
Illuminates when remote control is connected to the antenna
entry panel. Remote control now assumes acquisiti on
6
MGC Control
control.
Section II. OPERATION UNDER USUAL CONDITIONS
3-3.
Scope
Unit and control
Position
a. This section contains instructions and
Amplifier/Mixer (fig.3-5) (two)
AC POWER ON Switch
OFF (down)
procedures for applying power to the equipment, placing
Other Switches
Any
it into operation, and shutting down the equipment. The
Waveguide Switch w/Air Vent
procedures assume that the installation procedures
described in chapter 2 have been accomplished.
AIR VENT
b. If the terminal is being started up from a
PA1-ONLINE-PA2 Switch
As Required for
Terminal configuration
must be performed in sequence.
As Required for
c. If the terminal is being started up following a
All switches
Terminal configuration
short-interval shutdown, proceed to the applicable text in
BLOWER Switch
OFF
the following paragraphs as required to place the
START Switch
OFF
equipment into the system.
Other Switches
As Required for
NOTE
terminal configuration
Ensure that all external and internal
roadside
ventilation
ports
are
POWER ON Switch
Down (off)
adjusted as required.
Other switches
As required for
terminal configuration
3-4. Initial Control Settings
Set all controls to the positions indicated on all the units
POWER OFF-ON Switch
OFF
listed in table 3-17. These control positions are intended
Other Switches
As required for
merely to represent a cold-start initial setup and not a
terminal configuration
total shutdown of fully operational condition. Where
noted, do not disturb any mode assignment control
REGULATED 115 VAC ATTACH NOTE
positions from the last operational deployment.
HP 436A ONLY Outlet
Turn off power of any
Table 3-17. Preliminary Control Settings
equipment plugged
into this outlet.
Unit and control
Position
CUT KEY Switches
configuration
All OFF-ON Switches except
MAIN
LOOP CURRENT Switch
OFF
Power 1&2, and
LOW LEVEL TTY VOLTAGE
OFF
BLACKOUT INHIBIT
OFF (down)
Switch
MODE SELECT Switch
PA1/AIR COND 2,
MONITOR Switch
PA2/AIR COND 1
Multiplexer Selection and
As required for
Any
Channel
technical
Selection switches
configuration
FILTER SELECT Switch
WB
As required
Multiplexer AN/FCC-98
Check
that
E/F
POWER Switch
OFF
strapping is in F
Other Switches
ANY
position
refer
to
applicable technical
POWER:
manuals.
All OFF-ON Switches (three)
OFF
3-26